Urecon Pre-Insulated Pipe | Return to Home

Home | Career Opportunities | Contact | Search:

Applications Systems Heat Tracing Documents Learning Centre About URECON
 
 
null
                     

                    Urecon | Celebrating 40 Years | 1969-2009

                    Steel

                    Urecon Pre-Insulated Standard Wall, ASTM A53 Grade B Steel Core Pipe
                    Dimensions 13 mm to 300 mm (½ in to 12 in)

                    Nominal
                    Pipe Size
                    Outside
                    Pipe Dia.
                    Insulation O.D. Standard Wall Steel
                    Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
                    mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
                    13 ½ 21.3 0.84 108 4.25 133.00 5.25 15.75 0.62 2.77 0.11 2.74 1.85
                    19 ¾ 26.7 1.05 108 4.25 133.00 5.25 20.83 0.82 2.87 0.11 3.15 2.13
                    25 1 33.4 1.32 108 4.25 133.00 5.25 26.67 1.05 3.38 0.13 3.70 2.5
                    32 42.2 1.66 127 5.00 155.00 6.13 35.05 1.38 3.56 0.13 4.84 3.27
                    38 48.3 1.90 127 5.00 155.00 6.13 40.89 1.61 3.68 0.15 6.69 4.52
                    50 2 60.3 2.38 139 5.50 165.00 6.50 52.58 2.07 3.91 0.15 7.35 4.94
                    63 73.0 2.88 171 6.75 196.00 7.75 62.74 2.47 5.16 0.20 12.34 8.34
                    75 3 88.9 3.50 171 6.75 196.00 7.75 77.98 3.07 5.49 0.22 13.59 9.14
                    100 4 114.3 4.50 196 7.75 228.00 9.00 102.36 4.03 6.02 0.24 18.84 12.67
                    125 5 141.3 5.56 247 9.75 279.00 11.00 128.27 5.05 6.55 0.26 26.83 18.13
                    150 6 168.3 6.63 247 9.75 279.00 11.00 154.18 6.07 7.11 0.28 31.76 21.36
                    200 8 219.1 8.63 304 12.00 336.00 13.25 202.69 7.98 8.18 0.32 46.83 31.49
                    250 10 273.1 10.75 355 14.00 393.00 15.50 254.51 10.02 9.27 0.37 65.31 43.92
                    300 12 323.9 12.75 406 16.00 438.00 17.50 304.80 12.00 9.27 0.37 78.44 52.75
                    355 14 355.6 14.00 N/A N/A 476.25 18.75 336.55 13.25 9.27 0.37 86.57 58.22
                    400 16 406.4 16.00 N/A N/A 520.70 20.50 387.35 15.25 9.27 0.37 99.14 66.67
                    450 18 457.2 18.00 N/A N/A 577.85 22.75 438.15 17.25 9.27 0.37 111.64 75.08
                    500 20 508.0 20.00 N/A N/A 628.65 24.75 488.95 19.25 9.27 0.37 124.19 83.52
                    1. Larger sizes and other schedules also available.
                    2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
                    3. Insulation thickness for Latin America/Caribbean (UreconRED and Urecon BLUE) nominal 25 to 37mm (1 to 1.5 in.) depending on diameter; other thicknesses available upon request.
                    4. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
                    5. Jacketing 1.,27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
                    6. Standard single random and double random lengths available.
                    7. Specify pipe jointing method to ensure that proper joint insulation kits are supplied.

                    Urecon Pre-Insulated Extra Heavy Wall, ASTM A53 Grade B Steel Core Pipe
                    Dimensions 13 mm to 300 mm (½ in to 12 in)

                    Nominal
                    Pipe Size
                    Outside
                    Pipe Dia.
                    Insulation O.D. Extra Heavy Wall Steel
                    Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
                    mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
                    13 ½ 21.3 0.84 108 4.25 133.00 5.25 13.72 0.54

                    3.73

                    0.15 3.09 2.09
                    19 ¾ 26.7 1.05 108 4.25 133.00 5.25 17.36 0.75 3.91 0.15 3.66 2.47
                    25 1 33.4 1.32 108 4.25 133.00 5.25 24.38 0.96 4.55 0.18 4.70 3.17
                    32 42.2 1.66 127 5.00 155.00 6.13 32.51 1.28 4.85 0.19 5.92 4.00
                    38 48.3 1.90 127 5.00 155.00 6.13 38.10 1.50 5.08 0.20 6.85 4.63
                    50 2 60.3 2.38 139 5.50 165.00 6.50 49.27 1.94 5.54 0.22 8.90 6.02
                    63 73.0 2.88 171 6.75 196.00 7.75 58.93 2.32 7.01 0.28 13.14 8.88
                    75 3 88.9 3.50 171 6.75 196.00 7.75 73.66 2.90 7.62 0.30 16.98 11.47
                    100 4 114.3 4.50 196 7.75 228.00 9.00 97.03 3.82 8.56 0.34 24.38 16.47
                    125 5 141.3 5.56 247 9.75 279.00 11.00 121.92 4.80 9.53 0.38 34.45 23.28
                    150 6 168.3 6.63 247 9.75 279.00 11.00 146.56 5.77 10.97 0.43 45.13 30.49
                    200 8 219.1 8.63 304 12.00 336.00 13.25 193.80 7.63 12.70 0.50 67.67 45.72
                    250 10 273.1 10.75 355 14.00 393.00 15.50 247.65 9.75 12.70 0.50 86.39 58.10
                    300 12 323.9 12.75 406 16.00 438.00 17.50 298.45 11.75 12.70 0.50 103.05 69.30
                    355 14 355.6 14.00 N/A N/A 476.25 18.75 330.20 13.00 12.70 0.50 113.68 76.45
                    400 16 406.4 16.00 N/A N/A 520.70 20.50 381.00 15.00 12.70 0.50 130.77 87.67
                    450 18 457.2 18.00 N/A N/A 577.85 22.75 431.80 17.00 12.70 0.50 146.95 98.82
                    500 20 508.0 20.00 N/A N/A 628.65 24.75 482.60 19.00 12.70 0.50 163.60 110.02
                    1. Larger sizes and other schedules also available.
                    2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
                    3. Insulation thickness for Latin America/Caribbean (UreconRED and Urecon BLUE) nominal 25 to 37mm (1 to 1.5 in.) depending on diameter; other thicknesses available upon request.
                    4. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
                    5. Jacketing 1,27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
                    6. Standard single random and double random lengths available.
                    7. Specify pipe jointing method to ensure that proper joint insulation kits are supplied.